Fan Coil Unit

 

 

    

 Features

Freon Indoor Unit 

l         Unique motor design, minimize noise to the lowest.

l         Humanized design meets different installment demands.                

l         Strict electric protection design, more safety.

l         Patented diffusing apparatus design keeps high energy efficiency.

l         T1/T3 indoor units can meet the customers’ requirements

l         R22/R407Cindoor units can meet the customers’ requirements

Ceiling/Floor type

l         Saving space.

l         Auto flap function is a standard feature which provides optimum airflow during heating or cooling operation.

l         Quiet operation.

l         Multi air duct multi fan design.

l         Wide angle airflow in three dimensions.

l         Long life high efficiency air purifying.

l         Powerful dehumidification;

l         The maintenance space required is smaller.

l         Easy to overhang;

Cassette Type

       Heat exchanger adopting Aluminum Foil/Inner Copper tube, high efficiency.

       High control technology, long distance air supply.

       Large airflow, low noise due to large diameter scroll fan.

       Famous brand water pump discharge condensing water, to raise water height as high as 750mm.

       Touchable electric contactor controls the water level. When the condensing water height in the fan coil is beyond

the fixed height, the unit will stop running.

       Adjust temperature exactly, the difference within ±1℃,using delicate resistance temperature sensor.

       High efficiency sterilization filter screen to ensure the healthy new air cycle air.

       Fresh air opening can introduce part of outdoor fresh air, to keep the indoor air quality. 

Nomenclature

Freon Indoor Unit

European Type

 

Concealed Type

 

 

 

Ceiling/Floor Type 

   

 

 

 

 

 

Cassette Type

 

  

Technical Data

European Type

Model

VEGH018HCA

VEGH024HCA

VEGH030HCA

VEGH036HCA

Performance data

RATED COOLING*

 BTU/H

18,000

22,400

28,000

34,000

RATED HEATING

BTU/H

21600

26800

33500

38600

SEER 

BTU/H-W

10

10

10

10

Power

/

220-240/50/1

Voltage range

/

198-264

Max. overcurrent

A

0.08

0.17

0.15

0.26

Performance current

A

0.05

0.08

0.13

0.22

Min. wire capacity

A

0.04

0.075

0.12

0.20

Cycle airflow

m3/h

1020

1360

1700

2040

CFM

600

800

1000

1200

Coil data

Face  area

0.102

0.133

0.163

0.204

Number of Rows

N

3

3

3

3

Air-Filter

/

Plastic

Fins per Inch

 

13

13

13

13

Fans data

Quantity

pc

1

1

2

2

Drive method

 

Direct drive

Impeller

 

Volute type

Impeller quantity

pc

2

2

3

4

Refrigerant

Type

 

R22/R407C

Connecting pipe size

Liquid pipe

INCH/

3/8  /φ9.52

Gas pipe

INCH/

5/8   /φ15.88

Unit size

Length

INCH/

34-1/2 /877

42-3/8  / 1077

54-1/4 / 1377

66 / 1677

Width

INCH/

18 / 460

18 / 460

18 / 460

18 / 460

Height

INCH/

9  / 230

9  / 230

9  / 230

9  / 230

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


NOTES:

1. Indoor working conditioning: in cooling, temperature DB:27 (80 ), WB:1967

2. Fan Power is measured under high velocity running at the standard conditions.

3. The parameters are measured when the connecting pipe between outdoor unit and indoor unit is 7.5m.

 

As part of our continuous product improvement, Vicot reserves the right to change specifications and design without notice.

Technical Data 


Concealed Type

 

Model

VNGH018W

VNGH024W

VNGH030W

VNGH036W

VNGH048W

VNGH060W

 

Performance data

 

RATED COOLING*

 BTU/H

18,000

22,400

28,000

34,000

46,000

55,500

RATED HEATING

BTU/H

21600

26800

33500

38600

53500

64000

SEER 

BTU/H-W

10

10

10

10

10

10

Power

/

220-240/50/1

 

Voltage range

/

198-264

 

Air Circulation

m3/h

1020

1360

1700

2040

2720

3400

 

CFM

600

800

1000

1200

1600

2000

 

Refrigerant

 

Type

 

R22/R407C

 

Connecting pipe size

Liquid pipe

INCH/

3/8  /φ9.52

Gas pipe

INCH/

5/8   /φ15.88

3/4  /φ19.05

Unit size

 

Length

INCH/

413/4 / 1060

413/4 / 1060

673/8 / 1710

44-7/8 / 1140

58-5/8 / 1490

76-3/8 / 1940

Width

INCH/

20 / 510

20 / 510

20 / 510

25 / 636

25 / 636

25 / 636

Height

INCH/

9-7/8 / 250

9-7/8 / 250

9-7/8 / 250

13-1/8 / 335

13-1/8 / 335

13-1/8 / 335

Weight

Net

/lbs

28 / 61

28 / 61

38 / 83

42 /  92

47 /103

52 / 114

SHIPING

/lbs

31 / 68

31 / 68

41 / 90

45 / 98

50 / 110

56 / 123

NOTES:

1. Indoor working conditioning: in cooling, temperature DB:27℃ (80 ℉), WB:19℃67

2. Fan Power is measured under high velocity running at the standard conditions.

3. The parameters are measured when the connecting pipe between outdoor unit and indoor unit is 7.5m.

 

As part of our continuous product improvement, Vicot reserves the right to change specifications and design without notice.

 

Technical Data

Ceiling /Floor Type

 

Model

VNGH018W

VNGH024W

VNGH030W

VNGH036W

VNGH048W

VNGH060W

 

Performance data

 

RATED COOLING*

 BTU/H

18,000

22,400

28,000

34,000

46,000

55,500

RATED HEATING

BTU/H

21600

26800

33500

38600

53500

64000

SEER 

BTU/H-W

10

10

10

10

10

10

Power

/

220-240/50/1

 

Voltage range

/

198-264

 

Air Circulation

m3/h

1020

1360

1700

2040

2720

3400

 

CFM

600

800

1000

1200

1600

2000

 

Refrigerant

 

Type

 

R22/R407C

 

Connecting pipe size

Liquid pipe

INCH/

3/8  /φ9.52

Gas pipe

INCH/

5/8   /φ15.88

3/4  /φ19.05

Unit size

 

Length

INCH/

413/4 / 1060

413/4 / 1060

673/8 / 1710

44-7/8 / 1140

58-5/8 / 1490

76-3/8 / 1940

Width

INCH/

20 / 510

20 / 510

20 / 510

25 / 636

25 / 636

25 / 636

Height

INCH/

9-7/8 / 250

9-7/8 / 250

9-7/8 / 250

13-1/8 / 335

13-1/8 / 335

13-1/8 / 335

Weight

Net

/lbs

28 / 61

28 / 61

38 / 83

42 /  92

47 /103

52 / 114

SHIPING

/lbs

31 / 68

31 / 68

41 / 90

45 / 98

50 / 110

56 / 123

NOTES:

1. Indoor working conditioning: in cooling, temperature DB:27℃ (80 ℉), WB:19℃67

2. Fan Power is measured under high velocity running at the standard conditions.

3. The parameters are measured when the connecting pipe between outdoor unit and indoor unit is 7.5m.

 

Technical Data 


Cassette Type

 

 

Model

VCMC018NN2

VCMC024NN2

VCMC036NN2

VCMC042NN2

VCMC048NN2

Power supply

220V/50HZ(60HZ)/1Ph

Capacity

Cooling

Btu/h

17000

24000

34000

41000

48000

W

5000

7100

10000

12000

14000

Heating

Btu/h

18000

26000

38000

44000

52000

W

5200

7700

11000

13000

15000

Air circulation

m3/h

850

1300

1600

1800

1800

CFM

500

764

941

1058

1058

Suitable area

m2

2234

3050

5075

6090

70~100

refrigerant

R22/R407C

Input power

W

110

150

170

200

200

Running current

A

0.5

0.7

0.77

0.9

0.9

Connecting pipe

Liquid

mm

9.52

9.52

9.52

9.52

9.52

Gas

mm

16

16

19

19

19

Drain

mm

23

26

23

23

23

Unit size

Length

INCH/

22-1/2 / 570

32-5/8 / 830

32-5/8 / 830

32-5/8 / 830

32-5/8 / 830

Width

INCH/

22-1/2 / 570

32-5/8 / 830

32-5/8 / 830

32-5/8 / 830

32-5/8 / 830

Height

INCH/

9-1/2 / 240

9-1/2 / 240

9-1/2 / 240

9-1/2 / 240

9-1/2 / 240

Panel  size

Length

INCH/

25-1/2 / 650

37-3/8 / 950

37-3/8 / 950

37-3/8 / 950

37-3/8 / 950

Width

INCH/

25-1/2 / 650

37-3/8 / 950

37-3/8 / 950

37-3/8 / 950

37-3/8 / 950

Height

INCH/

1-1/8 / 30

1-1/8 / 30

1-1/8 / 30

1-1/8 / 30

1-1/8 / 30

Weight

Kg/lbs

23 / 50

35 / 77

40 /88

40 / 88

45 / 98

                   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1. Indoor working conditioning: in cooling, temperature DB:27℃ (80 ℉), WB:19℃67

2. Fan Power is measured under high velocity running at the standard conditions.

3. The parameters are measured when the connecting pipe between outdoor unit and indoor unit is 7.5m.

 

Our Technical Partners


Coldcare Nigeria Limited is in technical partnership with acclaimed world leaders in related engineering services. This has helped us in the areas of training as well as research and development. This way, we are able to remain relevant and up-to-date in the ever-evolving engineering world

Read More...

Our Clients...


Our success is vested in our client's success  and we do our best to keep their satisfactions as our paramount goal.

 Among our highly esteemed clients are  Airtel Nigeria, Nigerian Bottling Company Plc, Reftech A/S, Gurara Bottling Company Limited, Hassan Plastics Limited, 


Read More...

Health Safety & Environment


COLDCARE NIGERIA LIMITED places high premium on Health, Safety and Environment (HSE). Our policy makes it mandatory for everyone who works for the company, Including contractual to adhere strictly to HSE performance standards.

Read More...

OUR VISION

Our Vision is to be a household name of international standard in the provision of quality engineering products and services.

  OUR MISSION:

To keep to the ideal of high ethical standards in providing quality and efficient services to our customers at reasonable cost